Electrostatic Voltage Attenuation Test

Print

Summary

The electrostatic voltage is measured by Static Honest Tester after a plastic material is electrified and its half-life time is extrapolated from the consecutive attenuating curve of the electrostatic voltage with time.

(‎Related standard : JIS L1094)

Testing Machine

Static Honest Meter ①A Voltage Applying Part ②A Measuring Part
③A Turn Table ④A Sample Setting

Specimen and Measurement condition

Size: 45×45mm,
Thickness(max) = 5mmt
n=5
Voltage range: 0.1~3.0kV
Decay time: 0.1~120sec.
Temperature: 23±2℃
Humidity: 50±50%RH

Example

Fig. Electrostatic Voltage Attenuation Curve

Search Number 6G003

Download The Technical Note of This Exapmle.